Three Way Ball Valve
An ANV three way ball valve enquiry starts with the flow path. Review the flanged valve photographs, pneumatic assemblies and manual or pneumatic sectional drawing references, then send the connections required at each operating position.
For industrial flow diversion, line selection or a specified mixing arrangement, match the valve porting and operator to the process sequence. Confirm the common port, travel and stopping positions before approving the configuration.
- Flanged product views
- Pneumatic assembly details
- Two sectional references
- Flow-plan review
Select a three way ball valve by the flow plan
A 3-way ball valve may be described by its duty as a diverter, selector or switching valve. These names help explain the application, but the actual port diagram defines the connections.
L-port and T-port selection
An L-port three way ball valve commonly selects between two flow routes. A T-port configuration can provide additional combinations, including connections between three ports in specified positions. Check the available positions and sealing arrangement on the model drawing.
Do not select from the L or T name alone. Identify the common port, the required inlet and outlet connections, the permitted rotation and any all-closed requirement. Confirm whether line communication during switching is acceptable.
Match the actuator to the required positions
A pneumatic three way ball valve assembly needs more than an actuator of the right physical size. Travel, mechanical stops, stopping positions and controls must implement the required flow sequence.
Provide differential pressure, valve torque requirements, air supply, cycle frequency and the required action after loss of air or power. Ask for a position-by-position connection plan with the selected assembly.
Flanged three way ball valve specification review
The photographs show several configurations. The selected model datasheet, material list and approved drawing determine the supplied valve and accessory scope.
| Selection point | Product reference and information required |
|---|---|
| Valve family | Three way ball valve for specified industrial flow-routing duties. Confirm L-port or T-port construction and the required connections at each position. |
| End connections | Flanged connections are visible in the product photographs. Confirm nominal size, bore, flange standard, facing, drilling and installation dimensions. |
| Operating arrangement | Several photographs show pneumatic actuator assemblies. The separate manual sectional drawing is a construction reference; confirm which operator belongs to the selected model. |
| Pneumatic accessories | Selected views show air control accessories, a pressure gauge and a top-mounted position indicator. Confirm the accessory list, signal requirements and electrical ratings in the quotation. |
| Materials and limits | Specify body, ball, seats and seals. Request pressure-temperature limits and compatibility for the selected medium; photographs do not establish material grades. |
| Drawing reference | Q348F150LB appears in the supplied drawing filenames. It does not establish the model or rating of every photographed valve. The images have no dimensional callouts or material schedules. |
| Documents | Request a model datasheet, dimensional drawing, port flow plan, material list and agreed inspection records. List required certifications for confirmation. |
For general flange terminology, see ASME’s B16.5 flange standard overview ↗. This reference explains the standard’s scope and does not establish this valve’s flange standard or certification.
Three way ball valve sectional drawings
Compare the supplied lever-operated and pneumatic construction references. Open each image for a closer view, then request the model-specific dimensions and port flow chart for your order.
Manual Three Way Ball Valve Sectional Drawing
Pneumatic Three Way Ball Valve Sectional Drawing
A sectional view illustrates construction at the shown section. It does not replace a complete operating-position diagram or establish interchangeability between the photographed assemblies.
7 essential checks for better selection
Use these details to prepare an accurate three way ball valve enquiry and a configuration-specific quotation.
-
Required flow connections
Mark the common port and the connections required at each position. Include both normal operation and any isolation position.
-
Switching sequence
State whether communication between lines is permitted while the ball moves. Identify any process requirement to prevent cross-contamination.
-
Medium and service conditions
Provide fluid composition, concentration, normal and design pressure and temperature. Describe solids, abrasion, vacuum or unusual cycling duties.
-
Size and connections
Specify nominal size, required bore, flange standard, facing and drilling. For a replacement, provide the existing installation dimensions.
-
Operator and control
Specify manual or pneumatic operation, travel, stopping positions and required action on loss of air or power. Provide air supply and control accessory requirements.
-
Materials and documents
Request the selected body, ball, seat and seal materials. List required drawings, test records and applicable certificates for confirmation.
-
Quantity and destination
Provide quantities by size, delivery destination and required delivery date. Include spare parts, identification and packing requirements.
Three way ball valve selection questions
Answers for buyers reviewing L-port versus T-port flow, pneumatic operation, actuator travel and quotation requirements.
What is a three way ball valve?
A three way ball valve routes flow among three connections. Select it by the required port connections, operating positions and process conditions, rather than by the number of connections alone.
What is the difference between L-port and T-port configurations?
The names describe the ball flow-path shape. An L-port commonly selects between two routes; a T-port can provide additional connections in specified positions. Check the model flow diagram, rotation and stops before selection.
Can a three way ball valve shut off all ports?
An all-closed position must be confirmed for the specific valve, seat arrangement and operating sequence. Do not assume full isolation from an L-port or T-port description alone.
Does the pneumatic actuator need 90 or 180 degrees of travel?
The required travel depends on the flow plan and stopping positions. Match the valve stops, actuator travel and control arrangement to the connections required at every position.
Can the valve provide precise mixing-ratio control?
Do not treat a standard flow-routing ball valve as a precision mixing controller. If proportional control is required, specify the control objective and request flow and control data for an appropriate configuration.
What happens after loss of air or power?
Specify which ports must remain connected or isolated after loss of air or power. The result depends on the selected actuator, accessory arrangement and valve position plan.
Does Q348F150LB confirm the rating of every photographed valve?
No. Q348F150LB appears in the two supplied drawing filenames. Confirm the actual model, pressure class, materials and connection standard in the approved technical documentation.
What information is needed for a quotation?
Send the port arrangement and required flow sequence, medium, pressure, temperature, size, flange standard, operator requirements, quantity and destination. Attach any existing drawings and document requirements.
Compare other ANV ball valve configurations
Browse the three-way ball valve category or review industrial floating ball valves for other isolation duties. Choose the flow-routing function first, then confirm the specific valve construction and operating limits.
Send your port arrangement and operating conditions
For a three way ball valve quotation, send the flow diagram and required connections at every position. Include service conditions and operator requirements so the valve and controls can be reviewed together.
Useful details to attach
- Port diagram and operating sequence
- Medium, pressure and temperature
- Size, bore and flange standard
- Operator and failure-position requirements
- Quantity, documents and destination

